Applications
- Level measurement
- Automation control
- Proximity
- Obstacle avoidance
- Robotics
Highlights
- Best Operating Frequency: 125 kHz, ±4%
- Minimum Transmit Sensitivity at Best Transmit Frequency: 107 dB re, 1µPa/V at 1 m
- Minimum Receive Sensitivity at Best Receive Frequency: -169 dB re 1V/µPa
- Minimum Parallel Resistance: 420 Ω, ±30%
- Minimum and Maximum Sensing Range*: 15 cm to 7 m
- Typical Sensing Range: 20 cm to 3 m
- Free (1 kHz) Capacitance: 1,000 pF, ±20% pF
- Beamwidth (@ -3 dB Full Angle): 12°, ±2°
- Maximum Driving Voltage (2% Duty Cycle Tone Burst): 800 Vpp
- Operating Temperature: -40°C to 90°C
- Weight: 20 g
- Housing Material: Glass filled polyester
- Acoustic Window: Glass reinforced epoxy
*Pulse-Echo Mode. Minimum and maximum ranges are best case scenarios. Actual range may vary, depending on drive circuitry and signal processing.
Features
- Rugged sealed construction
- Cylindrical design allows for installation in various applications
Options
- Optional circuit board mounting pins
- Available in PVDF housing for use in chemical aggressive environments